Milwaukee M12 IR Návod k obsluze

Procházejte online nebo si stáhněte Návod k obsluze pro Elektrické nářadí Milwaukee M12 IR. Milwaukee M12 IR Operator`s manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
OPERATOR’S MANUAL
Cat. No.
2260-21
M12™ 160x120 Thermal Imager


Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - OPERATOR’S MANUAL

OPERATOR’S MANUALCat. No. 2260-21M12™ 160x120 Thermal Imager

Strany 2 - 

8 M12 160x120 Thermal Imager Operator’s Manual3. To remove it, press it in gently and it releases so you can pull it out. 4. If an SD card is not i

Strany 3 - 

M12 160x120 Thermal Imager Operator's Manual 9Figure 4 and Table 2 identify the location and explain the function of the bu

Strany 4

10 M12 160x120 Thermal Imager Operator’s ManualTable 2. Controls and FeaturesNo. Name Function1 Hand grip Grip this when you use the Thermal Imager.

Strany 5 - 

M12 160x120 Thermal Imager Operator's Manual 11No. Name Function13 (Toggle button)Press to toggle between thermal image display and visual ima

Strany 6 - 

12 M12 160x120 Thermal Imager Operator’s ManualFigure 5. Elements of the Thermal Image Display 226174.3˚F9876584123Table 4. Explanation of Display El

Strany 7

M12 160x120 Thermal Imager Operator's Manual 13LOW BATTERY100%75%50%25%<10%Figure 6. Battery Fuel Gauge Levels and Imminent Shutdown Warning

Strany 8 - 

14 M12 160x120 Thermal Imager Operator’s ManualProceed as follows to capture and save a basic image set: 

Strany 9

M12 160x120 Thermal Imager Operator's Manual 15230138.9˚F95CANCELSAVEFigure 9. SAVE or CANCEL a New Image7. To write the image to SD card, pres

Strany 10 - 

16 M12 160x120 Thermal Imager Operator’s ManualFigure 10. Live Visual Camera ViewPress again to return to the thermal image view.

Strany 11 - 

M12 160x120 Thermal Imager Operator's Manual 17• Auto or Manual Range (default is Auto) – Gives you control over the lowest and highest tempera

Strany 12

Safety Information ...

Strany 13 - Table 3. Symbology

18 M12 160x120 Thermal Imager Operator’s ManualEmissivity is the ratio of a target surface’s infrared output (radiance) to that of a blackbody at the

Strany 14

M12 160x120 Thermal Imager Operator's Manual 19When you turn on the Thermal Imager, it is always in AUTO RANGE mode.

Strany 15 - LOW BATTERY

20 M12 160x120 Thermal Imager Operator’s Manual2. Press to select MANUAL range. The display appears as in Figure 13 (this example is using a diffe

Strany 16 - SETTINGS

M12 160x120 Thermal Imager Operator's Manual 211. From the live view mode, press then if needed to select COLOR, then . This opens the menu

Strany 17

22 M12 160x120 Thermal Imager Operator’s Manual1 Press and to select the menu item to set, followed by t to conrm your slection.2. Press and

Strany 18

M12 160x120 Thermal Imager Operator's Manual 23PHYSICAL AND ENVIRONMENTALDrop test 3’ (1m) drop to concrete Operating temperature r

Strany 19 - 

24 M12 160x120 Thermal Imager Operator’s ManualVISUAL IMAGINGVisual digital camera resolution 1.3 MegapixelsField of View 56º Horizontal X 46º Vertic

Strany 20 - MATERIAL

M12 160x120 Thermal Imager Operator's Manual 25Term Denition160x120 The number of pixels (picture elements or dots) in a saved thermal

Strany 21 - 

26 M12 160x120 Thermal Imager Operator’s ManualCD Compact Disk. Also called a CD ROM, for CD Read-Only Memory. The CD supplied with the Thermal Image

Strany 22 - MANUALAUTO

M12 160x120 Thermal Imager Operator's Manual 27xed focus An optical system for a camera or thermal imager that is set to one average distance,

Strany 23 - 

M12 160x120 Thermal Imager Operator's Manual 1Failure to follow the warnings

Strany 24 - 

28 M12 160x120 Thermal Imager Operator’s Manualinfrared (IR) Electromagnetic energy in wavelengths that are between visible light and RF (radio frequ

Strany 25 - 

M12 160x120 Thermal Imager Operator's Manual 29menu On the Thermal Imager, a menu is a list of choices you can make for settings, such as time,

Strany 26

30 M12 160x120 Thermal Imager Operator’s Manualresolution Same as “thermal sensitivity.” The number of meaningful digits in a temperature reading, fo

Strany 27 - 

M12 160x120 Thermal Imager Operator's Manual 31storage temperature The lowest ambient temperature to the highest ambient temperature in which yo

Strany 28

32 M12 160x120 Thermal Imager Operator’s ManualtogglePress the button to switch between thermal visual image display and visual image display. the d

Strany 29

M12 160x120 Thermal Imager Operator's Manual 33

Strany 30

MILWAUKEE ELECTRIC TOOL CORPORATION13135 West Lisbon Road • Brookeld, Wisconsin, USA 5300558-14-2260 11/11

Strany 31

2 M12 160x120 Thermal Imager Operator’s ManualFederal Communications Commission WARNING: Changes or modications to this unit not expressly approved

Strany 32

M12 160x120 Thermal Imager Operator's Manual 3226174.3˚F98Figure 1. Thermal Imager and a Thermal ImageModel 2260-21 M12™ 160x120 Th

Strany 33

4 M12 160x120 Thermal Imager Operator’s ManualAll of the manuals needed to safely and properly operate the Thermal Imager are a

Strany 34

M12 160x120 Thermal Imager Operator's Manual 5Visit www.milwaukeetool.com online and click on Service. Th

Strany 35

6 M12 160x120 Thermal Imager Operator’s ManualThe complete system comes packed in a rugged portable hard case. Figure 2 and Table

Strany 36 - 

M12 160x120 Thermal Imager Operator's Manual 7No. Item Model or Part Number1 Hard Carry Case 42-55-22652 Reference Card 58-22-02403 Product CD w

Komentáře k této Příručce